Every extinguisher's monthly look, annual maintenance and next hydro test on one board, with the record an OSHA inspector asks for kept a year past its last entry.
Each date this app counts and each check it runs on a save is listed here with its source and the day we last read it. Where a rule lives in a paid standard, we cite it and keep the same facts in our own layout; we never copy the standard's text or forms.
12
sourced rules in this trade, each read on or after Oct 28, 2026.
Hydrostatic test: 1 to 12 years, set on each extinguisher as its hydro interval for a type not in table l-1, from the last hydrostatic test.From 29 CFR 1910.157(f)(2) and Table L-1 Portable fire extinguishers (osha.gov), checked Oct 28, 2026. Some records run on a different interval, which the app applies from the record.
Rule
What it checks when you save
The annual maintenance date is kept for one year after the last entry or the life of the shell, whichever is less. Each entry here is held for one year from its date.From 29 CFR 1910.157(e)(3) Portable fire extinguishers (osha.gov), checked Oct 28, 2026.
Stops the save
A refillable stored-pressure dry chemical unit with a 12-year hydro is emptied and maintained every six years, so its six-year date is needed to schedule the next one.From 29 CFR 1910.157(e)(4) Portable fire extinguishers (osha.gov), checked Oct 28, 2026.
How long is the annual extinguisher maintenance record kept?
The annual maintenance date is kept for one year after the last entry or the life of the shell, whichever is less. Each entry here is held for one year from its date.From 29 CFR 1910.157(e)(3) Portable fire extinguishers (osha.gov), checked Oct 28, 2026.
A refillable stored-pressure dry chemical unit with a 12-year hydro is emptied and maintained every six years, so its six-year date is needed to schedule the next one.From 29 CFR 1910.157(e)(4) Portable fire extinguishers (osha.gov), checked Oct 28, 2026.
When the next one is due.
The same count the app keeps on every record, here without an account.
Unit or tag number, Location in building, Type, Container, Rating on the label, and more.
Inspection
Date, Inspected by, Monthly visual inspection done, Annual maintenance check done, Result, and more.
Hydrostatic test record
Date of test, Tested by, Signature of the person who tested, Serial number or other identifier, Test pressure, and more.
What your client receives.
The extinguisher inspection record, as the app issues it the moment the inspection is saved: signed, dated and frozen, with what is next due. This one is filled with invented records so you can read it before you sign up.